CO₂ Laser Tube Quality Warranty Requirements
1. Conditions Covered Under Warranty
The following issues are covered by our company's quality warranty, provided that the CO₂ laser tube is still within its warranty period:
1. Laser power degradation: The output power of a standard laser tube drops below 70% of its rated power. For tapered laser tubes (model-specific tubes), the output power drops below 85% of the rated power.
2. Uneven engraving results: If an engraving laser tube produces uneven engraving depth at the bottom of the engraved area, a sample of the engraving result must be provided when submitting the return request.
3. Internal or external tube cracks caused by material stress: This includes cracks in the inner tube, such as the discharge tube, cooling tube, or glass bead areas, as well as circular cracks in the outer tube.
4. Poor laser beam spot quality: If the laser tube produces an abnormal beam spot when tested by burning 5 mm acrylic at a distance of 1,500–2,000 mm, it may be returned or replaced directly. However, poor beam spot quality caused by incorrect support positions, installation direction, or clamping force is not covered by the warranty.
5. Failure to ignite or abnormal arcing: The laser tube is physically intact but fails to ignite or produces electrical arcing when supplied with the normal operating voltage.
6. Abnormal discharge tube color: The laser tube ignites normally, but the inside of the discharge tube shows an obviously abnormal color, such as white, purple, or blue, accompanied by a decrease in output power.
7. Water leakage from the cooling jacket: Leakage occurs in the water-cooling jacket without any external impact or physical damage.
8. Cracked output window: The output window lens is clean and shows no abnormal contamination, but the lens itself is cracked.
9. Damage discovered upon delivery: The customer discovers damage to the CO₂ laser tube after receiving it and submits a claim in accordance with our company's reporting requirements.
10. Water inside the laser tube: The inside of the laser tube is filled with water, but no obvious cracks are visible.
Note: All the above conditions must be verified by our After-Sales Service Department. If the issue can be confirmed, customers may be instructed to remove and return the front and rear tube ends directly. If the issue cannot be confirmed remotely, the complete laser tube must be returned to our company for inspection and verification.
2. Conditions Not Covered Under Warranty
The following situations are not covered by our company's quality warranty:
1. Expired warranty: The CO₂ laser tube has exceeded its specified warranty period.
2. Improper installation or cooling: The water outlet of the laser tube must always be positioned vertically upward during installation to ensure that air bubbles can be completely discharged. Damage caused by trapped air bubbles, inner tube bursting, or condensation resulting from excessive temperature differences in the cooling water is not covered.
3. Output window contamination or improper cleaning: Damage to the output window lens coating caused by contamination or incorrect cleaning methods, as well as output window condensation or cracking caused by excessive temperature differences in the cooling water, is not covered.
4. Improper handling of external dust protection lenses: For CO₂ laser tubes equipped with an additional external dust protection lens, unauthorized removal of the external lens or improper cleaning of the laser tube's own output window, resulting in contamination, scratches, or damage, is not covered.
5. Poor water quality: Failures caused by abnormal water quality, including contamination or blockage of the cooling tube, resulting in tube bursting, abnormal beam spots, or unstable output power, are not covered.
6. External damage or abnormal operating conditions: Cracks or other damage caused by human error, external impact, transportation, weather conditions, insufficient cooling water, or abnormal cooling conditions are not covered.
7. Damaged electrodes: Damage to the cathode or anode caused by external impact, resulting in abnormal operation or failure of the laser tube, is not covered.
8. Excessively high ambient temperature: Unstable laser output or abnormal beam spot quality caused by excessively high ambient temperatures is not covered.
9. Unauthorized repairs or disassembly: Damage resulting from unauthorized repair work on serviceable CO₂ laser tubes or removal of the high-voltage protective cap without prior approval from our company or supplier is not covered.
10. Excessive operating current: Damage caused by operating the laser tube above its specified current limit, resulting in severe blackening of the electrode cylinder, reduced output power, or abnormal beam spot quality, is not covered.
11. Severely shattered cooling tube: CO₂ laser tubes with severely shattered cooling tubes are not eligible for return or replacement.
12. Insufficient high-voltage protection: Damage caused by inadequate high-voltage insulation or protection during installation or operation is not covered.